Avaya 03-300430 User Manual

Page of 2574
ADX8D-PT (AUDIX Digital Port)
Issue 1 June 2005
351
 
While the primary information channel is still looped around, the Control Channel Looparound 
test is performed. The Looparound test for the secondary information (data) channel is then 
performed. This is the same test as the primary information channel’s loop-around test.
Next, a Conference test is implemented for the primary information channel. This is the same 
test as Conference test (#6).
Only one value (Pass, Fail, or Abort) is generated as a result of the four tests run. If any tests fail 
or abort, the sequence stops.
Table 95: Test #13 Voice and Control Channel Local Loop Test 
Error
Code
Test 
Result
Description / Recommendation
ABRT
Internal system error.
1. Retry the command at 1-minute intervals up to 5 times. Then try (b).
1000
ABRT
System resources required to run this test are not available. The port may 
be active.
1. Use display port location to determine the voice port extension 
of the port. Use status station to determine the service state of the 
port. If the service state indicates that the port is active, wait until it is 
idle before retesting.
2. Retry the command at 1-minute intervals up to 5 times.
1001
ABRT
System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
1002
ABRT
The system could not allocate time slots for the test. The system may be 
under heavy traffic conditions, or may have time slots that are 
out-of-service due to TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic, 
retry the command at 1-minute intervals up to 5 times.
1003
ABRT
The system could not allocate a tone receiver for the test. The system may 
be oversized for the number of Tone Detectors present, or some Tone 
Detectors may be out of service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals up 
to 5 times.
 1 of 2