Avaya 03-300430 User Manual

Page of 2574
ADX16D-P (16-Port AUDIX Digital Port)
Issue 1 June 2005
355
 
ADX16D-P (16-Port AUDIX Digital Port)
S8700 | 8710
 / 
S8500
!
CAUTION:
CAUTION:
Never do any of the following without first shutting down AUDIX. Follow the 
instructions on the TN566/TN2169 faceplate:
Remove EMBEDDED AUDIX circuit packs
Cycle power to a carrier containing EMBEDDED AUDIX circuit packs
Remove power to a carrier or cabinet containing EMBEDDED AUDIX circuit pack
The ADX16D-P MO represents a port on a TN566/TN2169 EMBEDDED AUDIX circuit pack 
operating in digital-port (DP) mode. The maintenance strategy for ports on the TN566 operating 
in control-link mode is described in ADX16A-PT.
The tests described in this section apply only to switch-side maintenance that tests a circuit 
pack’s components related to the TDM-bus interface. The AUDIX system has an extensive 
maintenance strategy that is described in DEFINITY AUDIX System Release 3.2.4 
Maintenance, 585-300-110
.
AUDIX resides on a combined pair of circuit packs: the TN566 Multifunction board (MFB) and 
the TN2169 Alarm board (ALB). Because of its size this combination occupies 5 slots, but the 
system sees only 1 slot as functional. The other 4 slots are seen by the switch as 
“AUDIX-reserved” slots (or ADX16-RES/ADX16D-RS).
In 16-port DP mode, the TN566 pack supports up to 16 voice ports, each with a primary and a 
secondary information channel. Ports are administered in increments of two. When a call to a 
station with an AUDIX login is not answered, AUDIX answers the call using one of the available 
voice ports.
Unlike other AUDIX systems, EMBEDDED AUDIX is not an adjunct.
MO Name in Alarm Log Alarm
Level
Initial Command to Run
Full Name of MO
ADX16D-P
MIN
WRN
test port location l  AUDIX Digital port