Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
360 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
1003
ABRT
The system could not allocate a tone receiver for the test. The system may 
be oversized for the number of Tone Detectors present, or some Tone 
Detectors may be out of service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
1004
ABRT
The port was put in use during the test. The test has been aborted.
1. Use display port location to determine the voice port extension 
of the port. Use status station to determine the service state of the 
port. If the port is active, it is unavailable for certain tests. Refer to 
“Status” commands in 
 in Maintenance 
Commands Reference (03-300191) for explanations of every possible 
state. Wait until the port is idle before testing.
1020
ABRT
Test disabled via background testing. 
1. Use status station to determine when the voice port is available 
for testing.
2000
ABRT
Response to the test request was not received within the allowable time 
period.
1. Retry the command at 1-minute intervals up to 5 times.
1, 2
FAIL
The NPE of the tested port was found to be transmitting in error. This 
causes noisy and unreliable connections. Failure code 1 indicates that the 
Crosstalk test failed on the primary channel. Failure code 2 indicates that 
the Crosstalk test failed on the secondary channel.
1. Replace the circuit pack (see caution at the beginning of this section).
PASS
The port is using its allocated time slots correctly.
1. To verify that this is not an intermittent problem, repeat this test up to 10 
times, and make sure it continues passing.
2. If complaints still exist, examine the connections.
Table 97: Test #9 NPE Crosstalk Test  (continued)
Error
Code
Test 
Result
Description / Recommendation
 2 of 2