Communication Manager Maintenance-Object Repair Procedures
364 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Error Log Entries and Test to Clear Values
Notes:
a. Error Type 1 is an in-line error that can only be resolved over time. No terminal equipment 
was present when ringing was attempted. Execute test port location s.
b. Error Type 23: The circuit pack was logically administered but not physically installed. The 
alarm will clear when the circuit pack is installed.
c. Error Type 130: The circuit pack was removed or has been insane for more than 
11 minutes. To clear the error, reseat or replace the circuit pack.
Table 99: EMBEDDED AUDIX Analog Line/Control Link Error Log Entries 
Error 
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each 
appropriate test’s description, and follow its recommended procedures.
0
Any
Any
Any
test port location sh r 1
1 (
40977
None
18
0
busyout 
station ext
WRN
ON
release station extension
23 (
0
None
WRN
OFF
130 
(
None
WRN
ON
test port location sh
257 
(
40973
None
513 
(
Any
None
1025 
(
Looparound test 
(#161)
MIN
WRN
2
2. Minor alarms on this MO may be downgraded to Warning alarms based on the values used in set options.
ON
test port location l r 2
1281
Conference test 
(#7)
MIN
WRN
2
ON
test port location l r 2
1537
NPE Crosstalk test 
(#6)
MIN
WRN
2
ON
test port location l r 2