Avaya 03-300430 User Manual

Page of 2574
ADX16A-PT (AUDIX Analog Line/Control Link)
Issue 1 June 2005
365
 
d. Error Type 257 is an in-line error and can only be resolved over time. Ringing voltage is 
absent. If only one analog circuit pack in the system has this problem, replace the circuit 
pack. If only analog circuit packs on a particular carrier have this error, the ringing generator 
may not be connected to this carrier. If analog circuit packs on many carriers have this error, 
check the ringing generator.
e. Error Type 513: AUDIX is not available to the switch. Check the AUDIX system, referring to 
f. Error Type 1025: The TDM bus is out of service. See 
System Technician-Demanded Tests:
Descriptions and Error Codes
Investigate tests in the order presented. By clearing error codes associated with the 
Looparound test (#161), you may also clear errors generated from other tests in the testing 
sequence.
NO-OP Tests
The maintenance strategy for EMBEDDED AUDIX emulates the one for ANL-16-L. The tests 
listed below apply only to ANL-16-L and not to EMBEDDED AUDIX. These tests always return 
PASS.
Battery Feed test (#35)
Audits and Updates test (#36)
Station Present test (#48)
Tests 36 and 48 ABORT when AUDIX is not running.
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
1
1. D = Destructive; ND = Nondestructive
Looparound test (#161)
X
ND
Conference test (#7)
X
ND
NPE Crosstalk test (#6)
X
ND