Avaya 03-300430 User Manual

Page of 2574
ADX16A-PT (AUDIX Analog Line/Control Link)
Issue 1 June 2005
369
 
Loop-Around Test (#161)
This test is designed to check the on-board transmission capabilities of the NPE on the analog 
port.
Table 102: Test #161 Loop-Around Test 
Error
Code
Test
Result
Description / Recommendation
ABRT
Could not allocate the necessary system resources for this test.
1. Retry the command at 1-minute intervals up to 5 times.
1000
ABRT
System resources required to run this test are not available. The port may 
be busy with a valid call.
1. Use display port location to determine the station extension. 
Use status station to determine the service state of the port. If the 
port is active, wait until it is idle before testing.
2. If the port status is idle, retry the command at 1-minute intervals up to 5 
times.
1002
ABRT
The system could not allocate time slots for the test. The system may be 
under heavy traffic conditions or it may have time slots out-of-service due to 
TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic, 
retry the command at 1-minute intervals up to 5 times.
1003
ABRT
The system could not allocate a tone receiver for the test. The system may 
be oversized for the number of Tone Detectors present, or some Tone 
Detectors may be out of service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals up to 
5 times.
1004
ABRT
The port was seized by a valid call during the test. The test has been 
aborted.
1. Use display port location to determine the station extension. 
Use status station to determine the service state of the port. If the 
port is active, wait until it is idle before testing.
2. Retry the command at 1-minute intervals up to 5 times.
 1 of 2