Communication Manager Maintenance-Object Repair Procedures
382 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
1000
ABRT
The test was aborted because system resources required to run this test 
were not available. The port may be busy with a valid call. Use display 
port PCSSpp
 to determine the station extension of the port. Use status 
station
 to determine the service state of the port. If the service state 
indicates that the port is in use, then the port is unavailable for certain 
tests. You must wait until the port is idle before retesting.
1. If the port is idle, retry the command at 1-minute intervals a maximum 
of 5 times.
1004
ABRT
The port received an EXT-DEV failure during the test. The test has been 
aborted.
1. Before retesting, enter test external-device-alarm port 
location to determine whether the port is reporting an EXT-DEV 
failure.
2. If the port has no EXT-DEV failures, retry the command at 1-minute 
intervals up to 5 times.
1006
ABRT
This port has been busied out by command.
1. Check Error Log for Error Type 18 (port busied out). If present, use 
release port location to release the port and run the test again.
2000
ABRT
Response to the test request was not received within the allowable time 
period.
1. Retry the command at 1-minute intervals up to 5 times.
2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1
FAIL
This failure does not indicate a hardware problem. The switchhook audit 
failed. This condition may occur when the audit is performed at the same 
time that the terminal equipment goes off-hook.
1. Before retesting, enter test external-device-alarm port 
location to determine whether the port is reporting an EXT-DEV 
failure. Wait until the port has no EXT-DEV failures.
2. If the port has no EXT-DEV failures, retry the command at 1-minute 
intervals up to 5 times.
7
FAIL
The translation update failed. This does not indicate a hardware problem 
but may be an internal software error.
Table 111: Test #36 Station Status and Translation Audits and Updates  (continued)
Error 
Code
Test
Result
Description / Recommendation
 2 of 3