Station Status and Translation Audits and Updates Test (#36)
This test updates the analog port’s message lamp state (if it has one) and translations with 
information in the software.
Table 116: Test #36 Station Status and Translation Audits and Updates 
Error
Code
Test
Result
Description / Recommendation
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1004
ABRT
The port was seized by a valid call during the test.  The test has been 
aborted.
1. Use display port location to determine the station extension. 
Use status station to determine the service state of the port. If the 
port is active, wait until it is idle.
2. Retry the command at 1-minute intervals up to 5 times.
3. If the test continues to abort and the port is not in use, escalate the 
problem.
1005
ABRT
The test was aborted due to a configuration problem.  This test may not be 
applicable, or it may be disruptive to terminal equipment other than a voice 
terminal (for example, the modem pool member or Music On Hold).
1006
ABRT
This port has been busied out by command, or taken out-of-service by the 
failure of the NPE Crosstalk test.
1. Look in the error log for error type 18 (port busied out) for this port. If 
this error is present, release the port with release station 
extension
, and run the test again.
2. Check the error log for error type 1025 (NPE crosstalk test failed) for 
this port. If this error is present, investigate the errors associated with 
the NPE Crosstalk test (#6).
3. Make sure that the terminal is connected and in service, and then 
retest.
2000
ABRT
Response to the test request was not received within the allowable time 
period.
1. Retry the command at 1-minute intervals up to 5 times.
2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
 1 of 2