400 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
1002
ABRT
The system could not allocate time slots for the test.  The system may be 
under heavy traffic conditions or it may have time slots out-of-service due 
to TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy 
traffic, retry the command at 1-minute intervals up to 5 times.
1003
ABRT
The system could not allocate a tone receiver for the test.  The system 
may be oversized for the number of Tone Detectors present, or some 
Tone Detectors may be out of service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals up 
to 5 times.
1004
ABRT
The port was seized by a valid call during the test. The test has been 
aborted.
1. Use display port location to determine the station extension. 
Use status station to determine the service state of the port. If 
the port is active, wait until it is idle.
2. Retry the command at 1-minute intervals up to 5 times.
1005
ABRT
This test is not run on ports administered as External Alert, Announcement 
or combined modem pool ports.  This error can be ignored.
1018
ABRT
The test has been disabled by administration. The default for the Test 
field on the station screen is y. Determine why this field was set to n on 
this station. It may be due to the ringing application Test #48, which can 
be customer or terminal disturbing.
1. To enable the test for the particular analog station being tested, enter 
change station extension.
2. Enter y in the Test field.
Table 118: Test #161 Loop-Around Test  (continued)
Error
Code
Test
Result
Description / Recommendation
 2 of 4