Avaya 03-300430 User Manual

Page of 2574
ANL-LINE (8-Port Analog Line)
Issue 1 June 2005
409
 
2000
ABRT
Response to the test request was not received within the allowable time 
period.
1. Retry the command at 1-minute intervals up to 5 times.
2100
ABRT
System resources required to run this test are not available.  Either a 
system allocation to get information about the port or to put the port into a 
service state failed or the attempt to put the port in connection with a tone 
source failed (this could be a Tone-Clock problem).  The Tone-Clock and 
Tone Detectors could be having a communication problem.  For example, 
the companding modes could be out of synchronization.
1. Retry the command at 1-minute intervals up to 5 times.
Table 120: Test #6 NPE Crosstalk Test  (continued)
Error
Code
Test 
Result
Description / Recommendation
 3 of 4