Communication Manager Maintenance-Object Repair Procedures
410 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Any
FAIL
This test can fail due to either on- or off-board problems. Off-board 
problems of concern include EXP-PN, EXP-INTF, and RMC-ENV faults, 
TDM-BUS faults, and faults associated with the Tone Detectors/Tone 
Generators. Clear every off-board problem before replacing the board. 
Keep in mind that a TDM-BUS problem is usually the result of a faulty 
board connected to the backplane or bent pins on the backplane.
1. Resolve any EXP-PN, EXP-INTF, and RMC-ENV errors.
2. Resolve TDM-BUS errors.
3. Resolve TONE-BD or TONE-PT errors.
4. Test the board when the faults from steps 1, 2, and 3 are cleared.  
Replace the board only if the test fails.
PASS
The port is correctly using its allocated time slots.  User-reported troubles on 
this port should be investigated by using other port tests, by examining 
station wiring, by examining the station, and by ensuring that the terminal is 
correctly translated as off-premises or on-premises.
Note:
Note:
This test always passes for circuit packs TN712 prior to 
Vintage 14 and TN742 prior to Vintage 6.
0
NO
BOARD
The test could not relate the internal ID to the port (no board).  This could 
be due to incorrect translations, no board is inserted, an incorrect board is 
inserted, or an insane board is inserted.
1. Verify that the board’s translations are correct.  Enter list config
and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, enter 
busyout board location
3. Enter reset board location
4. Enter release board location
5. Enter test board location long
This should re-establish the linkage between the internal ID and the port.  If 
not, dispatch to verify that a valid board is inserted.