Avaya 03-300430 User Manual

Page of 2574
ANL-LINE (8-Port Analog Line)
Issue 1 June 2005
421
 
Station Present Test (or Ringing Application Test) (#48)
This test provides a burst of ringing current to the terminal equipment and detects that current 
flows.  This test is to ascertain whether or not terminal equipment is connected to the port.
This test may cause some terminal equipment to ring briefly during daily maintenance.  If this 
ringing is disturbing the customer or the terminal equipment, it should be disabled using the 
Tests field of the station administration screen.  However, on some releases of the software, this 
action disables Tests #6, 47, and 35, as well as Test #48.
PASS
The port is able to provide an analog transmission path to the station 
equipment.  User-reported troubles on this port should be investigated by 
using other port tests, by examining station wiring, by examining the station, 
and by ensuring that the terminal is correctly translated as off-premises or 
on-premises.
Note:
Note:
This test always passes for circuit packs TN712 prior to 
vintage 14 and TN742 prior to vintage 6.
0
NO 
BOARD
The test could not relate the internal ID to the port (no board).  This could 
be due to incorrect translations, no board is inserted, an incorrect board is 
inserted, or an insane board is inserted.
1. Verify that the board’s translations are correct.  Enter list config
and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, enter 
busyout board location
3. Enter reset board location
4. Enter release board location
5. Enter test board location long
This should re-establish the linkage between the internal ID and the 
port.  If not, dispatch to verify that a valid board is inserted.
Table 123: Test #47 Loop Around and Conference Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 5 of 5