Avaya 03-300430 User Manual

Page of 2574
AN-LN-PT (Analog Line Port)
Issue 1 June 2005
445
 
2000
ABRT
Response to the test request was not received within the allowable time 
period.
1. Retry the command at 1-minute intervals up to 5 times.
2100
ABRT
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
FAIL
The reflective loop-around test failed.  This could cause noisy or unreliable 
connections, or users calling this port may hear an echo.  The problem can 
also be off-board.
1. Since a line seizure may affect the test, repeat the test at 1-minute 
intervals up to 5 times.
2. Use test board location short to run circuit pack tests to check 
the Tone Generator and the Tone Detector circuits on the IPSIs or the 
Tone Generator/Tone Detector circuit packs.
3. Resolve any problems on the Tone Generator or the Tone Detector 
circuit.
4. If the Tone Generator and Tone Detector circuits are functioning 
properly, determine whether a voice terminal is connected and wired 
properly.  Resolve any problems found.
5. If the test still fails, replace the analog line circuit pack.
PASS
The port provides an analog transmission path to the station equipment.  
Investigate user-reported troubles on this port by running other port tests, by 
examining station wiring, or by inspecting the station.
Table 131: Test #161 Analog Looparound Test  (continued)
Error
Code
Test
Result
Description / Recommendation
 3 of 4