457
 
ABRT
Internal system error.
1. Retry the command at 1-minute intervals a maximum of 5 times.
0-256
FAIL
Test failed. The error code indicates the total number of defective 
announcements that were found.
When TEST #209 fails with error code 0, the Global Checksum failed on the 
board, but no individual Checksum failed.
Note:
Note:
Since the announcements are recorded digitally, it is possible 
for the Announcement Checksum Test to fail but still have all 
the announcements sound uncorrupted. When an individual 
announcement fails the Checksum Test, always listen to the 
announcement first before taking any action (an 
announcement can be played back by dialing the 
announcement extension associated with the announcement 
number). If the announcement sounds corrupted, then 
rerecord it or delete it.
1. Look in the Error Log to determine the number of the first defective 
announcement. Play back the announcement. If the announcement 
sounds defective, rerecord it or delete it. If the error code was greater 
than one (indicating that there is more than one defective 
announcement), run this test again and repeat this step.
2. If after deleting and rerecording all defective announcements, the 
checksum test still fails, reset the circuit pack using reset board 
PCSS
 and run this test again.
3. If the test still continues to fail, reseat the circuit pack and restore all 
announcements with an appropriate time estimate (for example, 40 
minutes.) Then rerecord the lost announcements (that is, those 
recorded since the last save operation) and run this test again.
4. If the test still continues to fail, replace the circuit pack, and run this test 
again.
!
WARNING:
WARNING:
Replacing the circuit pack results in loss of integrated 
announcements. See 
beginning of this Maintenance procedure.
Table 135: TEST #209 announcement checksum test  (continued)
Error
code
Test
result
Description/ Recommendation
 2 of 3