Avaya 03-300430 User Manual

Page of 2574
ANN-PT (announcement port)
Issue 1 June 2005
473
 
1003
ABRT
The system could not allocate a tone receiver for the test. The system may 
be oversized for the number of Tone Detectors present or some Tone 
Detectors may be out-of-service.
1. Look for TTR-LEV errors in the Error Log. If present, refer to 
2. Look for TONE-PT errors in the Error Log. If present, refer to 
3. If neither condition exists, retry the test at 1-minute intervals a maximum 
of 5 times.
1024
ABRT
Announcement circuit pack blocked the test because an announcement 
download is in progress. If an announcement download is in progress, 
status data-module <announcement data extension> should 
show that the announcement data port is connected to a NETCON data 
channel, and the memory card should be active. (To determine the extension 
of the announcement data module, use list data-module.)
See Note (a) at end of table for more information.
1. Wait until download is finished (could take a maximum of 45 minutes), 
and then run the test again.
2. If the test continues to abort and there is no download in progress, 
escalate the problem.
2000
ABRT
Response to the test request was not received within the allowable time 
period.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
ABRT
Internal system error.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Table 142: TEST #206 playback speech memory array (PSMA) test  (continued)
Error
code
Test
result
Description/ Recommendation
 2 of 3