Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
474 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Notes:
The Announcement circuit pack can exhibit a condition that does not allow recording.
If the circuit pack gets locked into this state (this is an extremely rare condition), two of the 
Announcement Ports on the circuit pack (one of which is the record port) will be unusable by 
software. Also, save/restore announcements will not work, since the record port looks 
busy to the circuit pack. Note that software does not have any way of knowing this and attempts 
to use the ports.
to
254
FAIL
Test failed. The error code indicates the number of byte count errors found 
by the Tone Detector.
1. Reset the circuit pack via reset board PCSS and then run this test 
again. If the test continues to fail, replace the circuit pack (see Warning).
2. If there are recurring alarms on this port caused by this test failing, 
replace the circuit pack even if Step 1 works (see Warning).
!
WARNING:
WARNING:
Replacing the circuit pack results in loss of integrated 
announcements. Refer to 
255
FAIL
Test failed. The Announcement Port and the Tone Detector never 
synchronized. Check for active GPTD-PT errors, and refer to 
1. If there are no active GPTD-PT errors, reset the circuit pack via reset 
board PCSS and then run this test again. If the test continues to fail, 
replace the circuit pack (see Warning).
2. If there are recurring alarms on this port caused by this test failing, 
replace the circuit pack even if Step 1 works (see Warning).
!
WARNING:
WARNING:
Replacing the circuit pack results in loss of integrated 
announcements. Refer to 
PASS
This port can cleanly play announcements. User-reported troubles on this 
pack should be investigated using other port and circuit pack tests. Refer to 
on page 447 for a description of the 
circuit pack tests.
Table 142: TEST #206 playback speech memory array (PSMA) test  (continued)
Error
code
Test
result
Description/ Recommendation
 3 of 3