ASAI-EPT
Issue 1 June 2005
489
 
Table 147: ASAI cause values 
Code Explanation
Recommendation
0
Unrecognized 
ASAI Protocol 
Operation.
Requested ASAI protocol is not implemented by switch or adjunct.  
Aux Data field of error log entry contains protocol identifier for 
unrecognized operation.
1. Consult switch and adjunct documentation to determine which 
set of operations is supported by switch and the adjunct.  
Turning off adjunct operations not implemented by the switch 
may resolve the problem.
34
No circuit or 
channel 
available
A resource on the switch is unavailable for a call.  For BRI 
endpoints, this cause value is not logged.  For ASAI, this condition 
means that there are no available trunks for an outgoing call 
request.
1. Verify that the adjunct is administered to support the trunk 
capabilities of the switch.
2. Investigate trunk-group status by issuing status trunk from 
the SAT or by requesting trunk-group queries from the adjunct.
3. Perform trunk diagnostic procedures outlined in this manual.
40
Resources 
not available.
No available internal resources to service switch or adjunct request.  
Exceeds system transaction capacity for adjunct or switch.
1. May require re-engineering of adjunct services.
 1 of 3