ASAI-EPT
Issue 1 June 2005
491
 
System Technician-Demanded Tests:
Descriptions and Error Codes
Investigate errors associated with the circuit pack and port first.  Clearing these error codes may 
also clear errors against the endpoint.  When every circuit pack and port error has been cleared, 
but errors still exist against the endpoint, investigate errors in the table below. 
BRI Layer 3 Query Test (#629)
This test is not used by the ASAI-ADJ MO. For information about this test, see 
69
Requested 
facility not 
implemented
Requested service not supported in switch or endpoint.
1. Consult switch and endpoint documentation to determine 
service support.
79
Service or 
option not 
implemented
Requested service or option (or combination of selected options) is 
not supported (implemented) in switch or the adjunct.
1. Consult switch and adjunct documentation to determine ASAI 
service and options supported by both switch and adjunct. 
Re-administration of the switch-administered capabilities (see 
Customer Optional Feature screen) or those of the adjunct may 
be necessary to correct the problem.
81
Invalid CRV
An invalid CRV was sent by the adjunct.
1. This may indicate a CRV inconsistency between the switch and 
the adjunct.  See the CallVisor protocol reference manual.
87
Internal switch 
audit
There is an inconsistency in switch data records.
1. There is no action needed, since the switch has corrected the 
data inconsistency.
Table 147: ASAI cause values  (continued)
Code Explanation
Recommendation
 3 of 3
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
Signaling Link Status test (#626)
X
X
Nondestructive