Server Alarms
50 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
(
on page 54 describes the Duplication Memory 
board’s alarms and their troubleshooting procedures.) [See also, 
Both periodic and on-demand testing is provided for this MO. The periodic test runs the Read 
Error Register test at 15-minute intervals. On-demand testing includes the Read Error Register 
and Local Loop tests.
MO’s Name (in 
Alarm Log)
Alarm 
Level
Initial Linux Command to Run
Full Name of MO
DAJ1 or DAL1
MAJ
testdupboard
1
1.  See 
Server Dup Mem board
DAJ1 or DAL1
MIN
testdupboard
Server Dup Mem board
DAJ1 or DAL1
WRN
testdupboard
Server Dup Mem board
Table 9: Testdupboard command syntax and arguments
Argument
Description
Syntax: testdupboard [-s] | [-l] | [-t arg] | [-?]
no 
argument
Performs “short” test.
-s
Short test, performs read_err_reg test, this is also the default option.
-l
Performs “short” tests, and localloop test
-t
arg   Specific test to perform. Possible values for arg are:
 read_err_reg 
localloop.
-?
Usage (this).