Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
500 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
The Deactivated state indicates a problem with the ASAI circuit pack.  When in this state, the 
Level 1 interface is idle and is not trying to communicate with the BRI endpoints or adjunct.  
When an ASAI port is placed in the out-of-service state, Level 1 is also put into the deactivated 
state.  This could be due either to the system detecting a fault with the port or in response to a 
busyout port location request.
Table 152: Test #621 Level 1 Status Inquiry 
Error 
Code
Test 
Result
Description / Recommendation
1187
ABRT
The board, port, or station may have been busied-out by a technician.
1. Look in the Error Log for Error Type 18 (port busied out) for this port 
and ASAI-BD (board busied out). If this error type is present for 
ASAI-PT only, then release the port using release port 
location
 and run the test again. If the error is present for both 
ASAI-BD and ASAI-PT, then release the board with release port 
location
 and run the test again.
Note:
Note:
When you release a port, you release every port 
associated with it. If certain ports still need to be busied out, 
use busyout port location to busy them out.
2. Make sure the terminal is connected.
3. Retry the command at 1-minute intervals up to 5 times.
2000
ABRT
Response was not received from the circuit pack within the allowable time 
period.
1. If the test aborts repeatedly up to 5 times, reset the circuit pack using 
busyout board location and reset board location.
2. If the test aborts again, replace the circuit pack.
2012
ABRT
Internal system error
2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
 1 of 2