Communication Manager Maintenance-Object Repair Procedures
518 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
1018
ABRT
Test call disabled
1. Set the Maintenance field on the Trunk Group screen to y.
1020
ABRT
TN230x circuit-pack problem
1. See 
1024
ABRT
Maintenance/Test digital port active
1. Wait until amber and green LEDs on the Maintenance/Test circuit pack 
are OFF.
2. Rerun the test.
3. If the problem persists, see 
1113
ABRT
Signaling link failed
1. Check the results of Test #255 (Signaling Link State Check test).
1116
ABRT
Switch could not change the service state
1. See if calls are active.  Run status trunk grp#/mem#.
2. If a call is active, proceed as for Error Code 1119.
If not, check the Error and Alarm Logs and see 
1117
ABRT
ISDN service message outstanding
1. Wait 2 minutes.  Then try again.
1118
ABRT
Far-end not administered
1. Check the administration of the far end of the ATM trunk.  Run status 
trunk grp#/mem#.
2. Try the test again.
1119
ABRT
Test call aborted, normal call attempted
1. Wait for the call to finish normally, or drop it by running busyout 
trunk grp#/mem#.
2. When the trunk is idle, retry the test.
Table 164: Test #258 ISDN Test Call  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 2 of 5