Avaya 03-300430 User Manual

Page of 2574
ATM-DCH (ATM D-Channel Port)
Issue 1 June 2005
523
 
Hardware Error Log Entries and Test to Clear Values
Notes:
a. Error Type 0: Run the short test sequence first.  If every test passes, run the long test 
sequence.  Refer to each appropriate test’s description, and follow its recommended 
procedures.
b. Error Type 18: D channel busied out; no calls possible over this D channel.
c. Error Type 130: circuit pack removed or has been insane for more than 11 minutes.  To 
clear the error, reinsert or replace the circuit pack.
d. Error Type 1793: ATM Trunk circuit pack failed the Signaling Link Board check (#643).  
Resolve any ATM-TRK errors in the Error Log.
System Technician-Demanded Tests:
Descriptions and Error Codes
The command to test the ATM-DCH MO is test port location, where location is for 
ports 9-32.
Table 165: ATM D-channel Error Log entries 
Error
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0 (
0
Any
Any
Any
test port location
18 (
)
0
busyout port 
location
WRN
OFF
release port location
None
WRN
ON
test port location
)
Signaling Link Board 
check (#643)
test board location l
Table 166: System Technician-Demanded Tests: ATM-DCH
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
Signaling Link Board check 
(#643)
X
X
Nondestructive