Avaya 03-300430 User Manual

Page of 2574
ATM-EI (Expansion Interface Circuit Pack)
Issue 1 June 2005
543
 
1. If the system has duplicated PNC:
a. Test the ATM-EI (test board location l).
b. If Error 3585 is detected again, or if the board is not recognized anymore, replace the 
ATM-EI circuit pack.
2. If the system does not have duplicated PNC and the circuit pack is in a PN:
a. Replace the ATM-EI circuit pack.
Error Type 3586: Framer Looparound test (#1260) failed.
Aux Data (Error Code 3586 only):
3. If Error Type 3586 is detected again, replace the circuit pack.
v. Error Type 3841: The board received a message from the switch that it does not recognize, 
and the board responded with an inconsistent down link error message.  This error does not 
affect service, and no action is required.
w. Error Type 3842: The circuit pack received data from the packet bus faster than it could 
distribute the data to its endpoint.  This circuit pack should be able to recover by itself, and 
no action is necessary.
x. Error Type 3843: The firmware on the circuit pack is reporting a resource that is low.  This 
error does not affect service and no action is required.
y. Error Type 3999: The circuit pack sent a large number of control channel messages to the 
switch within a short period of time.
 
Aux Data
Description
2
Packet path failed
3
Circuit path failed
4
TDM loop cannot be created
5
Packet loop cannot be created
If
Then
Error Type 1538 is also 
present
Circuit pack is taken out of service 
Error Type 1538 is absent
Circuit pack is not taken out of service, but has generated 
50% of the messages necessary to be considered 
hyperactive.
This can be normal during heavy traffic.
If the error is logged during light traffic, it can indicate a 
problem with the circuit pack or the equipment attached to it.