Avaya 03-300430 User Manual

Page of 2574
ATM-EI (Expansion Interface Circuit Pack)
Issue 1 June 2005
547
 
1033
ABRT
The test cannot run because either the ATM-EI board is not administered, 
or there were no other PNs administered that had its ATM-EI board 
in-service.
1. Ensure that the board is administered as ATM PNC Expansion 
Interface circuit pack.
2. If the board is administered as ATM-EI circuit pack, then there has 
been some change in the ability of the ATM-EI circuit pack in the other 
PNs to communicate with the ATM-EI on the other end of its 
connection.
3. Using status port x (the port-network number where the board is 
administered), see if both ACL and EAL are up to this board.  If not, 
see the service procedure for SYS-LINK.
4. Check the Error Log for Error Type 1281 with Aux Data 27 (board 
cannot talk to the ATM switch).  See 
on page 538 for repair procedures.
5. If present, check both the ATM switch and the Communication 
Manager translations for consistent ATM addresses.  Reset the board, 
and see if the problem resolves.
6. Repeat Test #241.  If it continues to abort with this abort code, replace 
the board.
1394
ABRT
ABORT
1. See 
page 538 (Error Type 1281) with Aux Data 27 (board cannot talk to the 
ATM switch), and if present, check both the ATM switch and the 
Communication Manager translations for consistent ATM addresses.
2. Reset the board and see if the problem resolves.
3. Repeat the test.
Table 174: Expansion Interface 2-Way Transmission Test (#241)  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 3 of 8