Avaya 03-300430 User Manual
ATM-EI (Expansion Interface Circuit Pack)
Issue 1 June 2005
561
Figure 28: ATM Board Framer Loop-Around Test (#1260) (non-EAA, Packet Path)
Table 181: ATM Board Framer Loop-Around Test (#1260)
Error
Code
Code
Test
Result
Result
Description / Recommendation
1002
ABRT
The system could not allocate timeslots for the test. The system could be
under heavy traffic conditions or it could have timeslots out of service due
to TDM-BUS errors.
under heavy traffic conditions or it could have timeslots out of service due
to TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
retry the command at 1-minute intervals up to 3 times.
1003
ABRT
The system could not allocate a tone receiver for the test. The system
may be oversized for the number of Tone Detectors present, or some Tone
Detectors may be out of service.
may be oversized for the number of Tone Detectors present, or some Tone
Detectors may be out of service.
1. Verify that at least one Tone Detector resides in this PN. (Even without
a TTR-LEV error, the tested circuit pack’s PN could be missing a Tone
Detector.)
Detector.)
If missing, the test always aborts for this circuit pack, without harming
the system.
the system.
Note: A TN2182 Tone-Clock circuit pack must be of vintage B or
newer. If an earlier vintage circuit pack resides in a PN, this test
always aborts with this abort code.
newer. If an earlier vintage circuit pack resides in a PN, this test
always aborts with this abort code.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals up
to 3 times.
1 of 5
Tone clock
Tone detector
Tone detector
PNC mode
PNC mode
PNC mode
ATM
framer
looped
iodfpak AWF 040699
ATM
switch
Packet bus
(PPN)
TDM bus
(EPN X)
Packet bus
(EPN X)
Packet
interface
ATM
circuit
pack
ATM
circuit
pack
ATM
circuit
pack
ATM
expansion
archangel