ATM-EI (Expansion Interface Circuit Pack)
Issue 1 June 2005
563
 
1407
ABRT
This test cannot be run on an ATM-EI board that is on the active PNC 
because it cannot be busied out.  This error code indicates that PNC 
duplication is enabled.
1. Attempt to perform a PNC interchange with the reset pnc 
interchange command.
2. If the PNC interchange is successful, busyout the original 
ATM-Expansion Interface circuit pack with the busyout board 
location
 (address of the original ATM-EI board) command.
3. Retry the command.
2000
ABRT
 Response to the test was not received in the allowable time period.
1. Retry the command at 1-minute intervals up to 3 times.
2060
ABRT
The link on the packet bus being used to perform the test has failed.
1. Retry the command at 1-minute intervals up to 3 times.
2. If the test continues to abort, resolve any PKT-INTF errors.
2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2500
ABRT
Internal system error.
1. Retry the command at 1-minute intervals up to 3 times.
1
FAIL
The test did not detect the test tone through the loop-around connection.
Note:
Note:
The packet portion of this test was not run since the circuit 
portion failed.
1. Test the active Tone-Clock (test tone-clock location) in the PN 
that contains the defective ATM-EI circuit pack to verify that dial tone is 
being supplied.
2. If the Tone-Clock is healthy, test the ATM-EI circuit pack (test board 
location long).
3. If this test continues to fail, replace the ATM-EI circuit pack or 
transceiver.
4. Test the new ATM-EI circuit pack (test board location long).
Table 181: ATM Board Framer Loop-Around Test (#1260) (continued)
Error 
Code
Test 
Result
Description / Recommendation