Avaya 03-300430 User Manual

Page of 2574
ATM-INTF (TN2305/6)
Issue 1 June 2005
575
 
FAIL
The circuit pack failed to return the circuit pack code or vintage.
1. Retry the command up to 5 times.
2. If the problem continues, reset the circuit pack.
3. Retry the command up to 5 times.
PASS
Communication with this circuit pack is successful.
Any
NO
BOARD
This is normal if the test is being executed when:
1. The board is not physically in the system.
2. The system is booting.
Otherwise, there is some inconsistency in the date stored in the system.
1. Verify that the board is physically in the system.
2. Verify that the system is not in the process of booting.
3. Retry the command at 1-minute intervals up to 5 times.
Table 188: Test #52: Control Channel Loop-Around  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 2 of 2