ATM Impaired Paths
1. Examine the error log (display errors), atm setup-events log 
(list measurements atm svc-setup), and atm pnc-latency 
(list measurements atm latency) screens to help diagnose the 
problem, although the switch could be operating normally.  In this 
case, you should consider raising the Activation threshold and/or 
increasing the Timeout value on the ATM-RELATED System 
Parameters screen.  (change system atm).
Use list measurements atm svc-setup to see information 
about errors associated with connection numbers.
2. After entering the above command, note the time stamps shown in the 
list measurements atm setup-events screen.  Execute the 
above command periodically and note the time stamps.  If the time 
stamps have changed for a particular From Conn-To Conn pair, this 
indicates there are still setup failures/delays for that connection.
3. After verifying that every associated ATM endpoint is operating 
correctly, and if errors are still occurring, contact your local service 
provider.
301 (
ANY
System wide ATM Impaired Paths.
See the suggestions listed above to trouble shoot these errors.
769 (
)
ATM CLP (Cell Loss Priority) Bit Errors
1025 (
)
ATM Congestion Bit Errors
1281 (
)
ATM Cell Underrun Errors
1537 (
)
ATM Cell Overrun Errors
1793 (
)
ATM Lost Cells
Table 189: Error codes and Aux Data values ATM-NTWK  (continued)
Cause 
Code/ 
Error 
Type
Aux 
Data
Cause Codes Description 
 6 of 6