Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
620 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Error Log Entries and Test to Clear Values
Table 208: ATM-TRK Error Log entries 
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0
0
Any
Any
test board location
1(
a
)
None
MIN
ON
18(
b
)
0
busyout board 
location
MIN
ON
release board location
23(
c
)
0
None
MIN
ON
125(
d
)
None
MIN
ON
257(
e
)
Any
Control Channel Loop 
(#52)
MIN
ON
test board location r 
2
513(
f
)
Any
ATM Cross Talk (#1298)
MIN
ON
test board location l 
r 1
769(
g
)
35
ATM Error Query (#1259)
WRN
OFF
test board location
770(
g
)
25
ATM Error Query (#1259)
WRN
OFF
test board location
771(
h
)
26
ATM Error Query (#1259)
WRN
OFF
test board location
1281(
i
)
ATM Board Error Query 
(#1259)
WRN
/ MIN
OFF
test board location r 
1
1537(
j
)
12
None
WRN
/ MIN
ON
1538(
k
)
0
None
WRN
/ MIN
ON
reset board location
1794(
l
)
13
None
MIN
ON
2049(
m
) 15
None
WRN
OFF
test board location
2306(
n
)
None
2561(
o
)
Packet interface test 
(#598)
MIN
ON
test board location r 
2
2817(
p
)
1-24 ATM Board DSP (#1293)
WRN
/ MIN
ON
test board location 
 1 of 2