Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
624 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
18
Multiplexer 
Section Alarm 
Indication 
Signal: 
MS_AIS
There is a major problem on the far end (between multiplexer 
section [MUX] and the switch) that prohibits the circuit pack from 
sending a valid signal.
1. See if the ports at the MUX and/or the ATM switch are 
connected snugly.
2. Run test board location.
3. If Test #1259 fails with Error Code 18, connect a fiber 
back-to-back in a looped mode (one strand of fiber connecting 
the transmit transceiver to the receive transceiver of the board) 
and see if the amber LED flash goes away.
4. If it does the problem is off-board.
5. If the amber LED continues to flash, replace the circuit pack; if 
the error persists, escalate the problem.
19
Multiplexer 
Section 
Remote Defect 
Indicator: 
MS_RDI
The far end is detecting a major problem with the signal that this 
board is transmitting.
1. Make sure the ATM switch port (or a MUX port, if present 
between ATM switch and the ATM-TRK board) is the same as 
the ATM-TRK circuit pack’s cable interface 
2. Run test board location.
3. If Test #1259 fails with Error Code 19, connect a fiber 
back-to-back in a looped mode (one strand of fiber connecting 
the transmit transceiver to the receive transceiver of the board) 
and see if the amber LED flash goes away.
4. If it does the problem is off-board.
5. If the amber LED continues to flash, replace the circuit pack; if 
the error persists, escalate the problem.
20
Loss of pointer: 
LOP
ATM framer chip is unable to access the payload part of the signal.
1. Reset the board with reset board location.
2. If the error persists replace the board.
21
Path Signal 
Error (PSL) 
(STM1/
SONET)
The incoming signal payload is not set up for transmission of ATM 
data.
1. Make sure the ATM switch port (or a MUX port, if present 
between ATM switch and the ATM-TRK board) is the same as 
the ATM-TRK circuit pack’s cable interface.
Table 209: Error type 1281 Aux Data and repair procedures  (continued)
Aux 
Data
Alarm 
Description
Repair procedure
 2 of 3