Avaya 03-300430 User Manual

Page of 2574
ATM-TRK (Circuit Emulation Service Circuit Pack)
Issue 1 June 2005
635
 
The test aborts if the ATM-TRK circuit pack is supplying synchronization.
Table 214: ATM Board Reset (#1256) 
Error 
Code
Test 
Result
Description / Recommendation
1005
ABRT
Wrong circuit pack configuration to run this test.  The ATM CES 
Trunk Interface circuit pack provides timing for the system and 
cannot be reset without major system disruptions.
1. Set synchronization to another ATM CES trunk circuit pack 
or to the Tone-Clock circuit pack and test again.
1015
ABRT
Test cannot be run because the ATM-TRK circuit pack has not 
been busied out.
1. Busyout out the circuit pack (busyout board location).
2. Repeat the test (test board location long).
None
ABRT 
Could not allocate the required system resources
1. Retry the command up to 5 times at 1-minute intervals.
2. If the test continues to abort escalate the problem.
2000
ABRT
Sanity test timed out.
1. Wait 5 minutes.  Then see if ATM-TRK circuit pack is visible 
to the system by running list configuration all.
2. If the ATM-TRK circuit pack is visible (list 
configuration all), run the test again, and escalate if 
the problem recurs.
3. If the ATM-TRK circuit pack is not visible to the system (list 
configuration all), re-seat the ATM-TRK circuit pack, 
and retest.
4. If the ATM-TRK circuit pack is still not recognized by the 
system, replace the board.
2100
ABRT
Could not allocate required system resources
1. Retry the command up to 5 times at 1-minute intervals.
2500
ABRT
Internal system error
1. Try to reset the circuit pack with reset board location.
 1 of 2