Avaya 03-300430 User Manual

Page of 2574
ATM-TRK (Circuit Emulation Service Circuit Pack)
Issue 1 June 2005
641
 
1033
ABRT
ATM-TRK circuit pack not found
1. See if the switch can see the circuit pack.  Run status 
trunk-group.
2. Retry the command.
1139
ABRT
Major alarm on the PN’s packet bus
1. Run display alarms, and perform the repairs associated with 
PKT-BUS errors.
2. Run display errors, and perform the repairs associated with 
PKT-BUS errors.
3. Retry the command.
1141
ABRT
Packet-interface circuit pack out of service
1. See 
1394
ABRT
ATM-TRK circuit pack out of service
1. Run ATM Board Reset Test #1256. 
2000
ABRT
 Request timed out.
1. Retry the command up to 3 times at 1-minute intervals.
2060
ABRT
Packet-bus link has failed.
1. Retry the command up to 3 times at 1-minute intervals.
2. If the test continues to abort, run display errors, and perform the 
repairs associated with PKT-INT errors.
2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
2500
ABRT
Internal system error
1. Retry the command up to 3 times at 1-minute intervals.
Table 218: ATM Board Framer Loop-Around Test (#1260)  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 2 of 4