Avaya 03-300430 User Manual

Page of 2574
ATM-TRK (Circuit Emulation Service Circuit Pack)
Issue 1 June 2005
643
 
5
FAIL
Unable to create packet-path loop.
1. Retry the command up to 3 times at 1-minute intervals.
2. If this test continues to fail, replace the ATM-TRK circuit pack.
3. Rerun test board location long.
6
FAIL
A previously established loop around was not released.
1. Run reset board location.
2. Retry the command up to 3 times at 1-minute intervals.
3. If this test continues to fail, replace the ATM-TRK circuit pack.
4. Rerun test board location long.
PASS
The non-optical parts of the ATM-TRK circuit pack are functioning properly.
0
NO
BOARD
ATM-TRK circuit pack not found
1. Check the error log for Error 125 (wrong board) or Error 131 (no board), 
and correct as necessary.
2. Check that the board is properly translated and inserted.
3. Check for Error 1538 (hyperactivity), and run reset board 
location if necessary.
4. Rerun test board location long.
5. If the test fails, replace the board, and rerun test board location 
long.
Table 218: ATM Board Framer Loop-Around Test (#1260)  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 4 of 4