Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
674 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
AXA12-RS (AUDIX Reserve Slots)
Error log entries and tests also apply to ADX8D-RD and AXD12-RS.
S8700 MC
There are no tests associated with these MOs.  Both test board and busyout board abort 
when either is attempted on a reserved slot.  An error message indicates that the slot is 
associated with the circuit pack that the TN568 is emulating, but the requested operation is not 
valid.  If there are errors logged against these MOs, see 
The TN568 circuit pack connects to the switch through a single slot in the backplane; however, 
the number of slots physically occupied by the circuit pack is supplied by the board when 
inserted.  The TN568 is 2 slots wide: the functional slot and a reserve slot.  The reserve (blank) 
slot to the left of the functional slot is a place holder on the switch and has no interaction with 
the switch.
These MOs are place holders for the extra slot needed for the EMBEDDED AUDIX board.  
Each instance of these MOs represents a reserve slot associated with the respective circuit 
pack mode in which the TN568 (EMBEDDED AUDIX) is working.  They are used for 
EMBEDDED AUDIX and emulation of respective port types.
MO Name in 
Alarm Log
Alarm 
Level
Initial Command to Run
Full Name of MO
AXA12-RS
NONE
NONE
TN568 12-port analog 
reserve slot
ADX8D-RS
NONE
NONE
TN568 8-port digital reserve 
slot
AXD12-RS
NONE
NONE
TN568 12-port digital 
reserve slot