BRI-PORT (ISDN-BRI Port)
Issue 1 June 2005
685
 
BRI-PORT (ISDN-BRI Port)
Error log entries and tests also apply to ABRI-POR, ATT-PORT, LGATE-PT, and ATTE-PT.
S8700 | 8710
 / 
S8500
Note:
Note:
Some of the information in this section is reserved for future use.
!
CAUTION:
CAUTION:
The section, 
 in Maintenance Procedures 
(03-300192),  along with the other information presented in the chapter, can help 
resolve problems involving more than one station or circuit pack.
!
WARNING:
WARNING:
If a significant packet-bus failure occurs, errors and alarms may not be logged as 
expected for BRI-PORT/ABRI-POR/ATT-PORT/ LGATE-PT/ ATTE-PT.  
Conditions under which this occurs are detailed in 
 in Maintenance Procedures (03-300192).
MO Name in 
Alarm Log
Alarm 
Level
Initial Command to Run
Full Name of MO
BRI-PORT
MIN
test port location l
ISDN-BRI port
BRI-PORT
WRN
test port location sh
ISDN-BRI port
ABRI-POR
MAJ
1
1. The alarm level for ASAI and Avaya adjunct ports may be administered using set options.  The alarm level 
can be set independently for on- and off-board alarms to WARNING, MINOR, or MAJOR for every ASAI 
and Avaya adjunct port in the system. 
All alarming for an ASAI and Avaya adjunct and OFF-BOARD alarming for an ASAI or Avaya port is 
disabled if the ASAI or Avaya adjunct asks the switch to suspend maintenance.  When this occurs, an error 
and a WARNING alarm is logged against the ASAI or Avaya adjunct.  The Hardware Error and Alarm Logs 
should be checked to see if the adjunct has disabled alarming.
test port location l
ASAI ISDN-BRI port
ABRI-POR
test port location l
ASAI ISDN-BRI port
ATT-PORT
MAJ 
test port location l
Avaya Adjunct ISDN-BRI port
ATT-PORT
WRN 
test port location l
Avaya Adjunct ISDN-BRI port
LGATE-PT
test port location l
Ethernet ASAI port
LGATE-PT
WRN 
test port location l
Ethernet ASAI port
ATTE-PT
test port location l
Ethernet Avaya Adjunct port
ATTE-PT
WRN 
test port location l
Ethernet Avaya Adjunct port