Avaya 03-300430 User Manual
BRI-PORT (ISDN-BRI Port)
Issue 1 June 2005
685
BRI-PORT (ISDN-BRI Port)
Error log entries and tests also apply to ABRI-POR, ATT-PORT, LGATE-PT, and ATTE-PT.
S8700 | 8710
/
S8500
Note:
Note:
Some of the information in this section is reserved for future use.
!
CAUTION:
CAUTION:
The section,
in Maintenance Procedures
(03-300192), along with the other information presented in the chapter, can help
resolve problems involving more than one station or circuit pack.
resolve problems involving more than one station or circuit pack.
!
WARNING:
WARNING:
If a significant packet-bus failure occurs, errors and alarms may not be logged as
expected for BRI-PORT/ABRI-POR/ATT-PORT/ LGATE-PT/ ATTE-PT.
Conditions under which this occurs are detailed in
expected for BRI-PORT/ABRI-POR/ATT-PORT/ LGATE-PT/ ATTE-PT.
Conditions under which this occurs are detailed in
in Maintenance Procedures (03-300192).
MO Name in
Alarm Log
Alarm Log
Alarm
Level
Level
Initial Command to Run
Full Name of MO
BRI-PORT
MIN
test port location l
ISDN-BRI port
BRI-PORT
WRN
test port location sh
ISDN-BRI port
ABRI-POR
MAJ
1
1. The alarm level for ASAI and Avaya adjunct ports may be administered using set options. The alarm level
can be set independently for on- and off-board alarms to WARNING, MINOR, or MAJOR for every ASAI
and Avaya adjunct port in the system.
All alarming for an ASAI and Avaya adjunct and OFF-BOARD alarming for an ASAI or Avaya port is
disabled if the ASAI or Avaya adjunct asks the switch to suspend maintenance. When this occurs, an error
and a WARNING alarm is logged against the ASAI or Avaya adjunct. The Hardware Error and Alarm Logs
should be checked to see if the adjunct has disabled alarming.
and Avaya adjunct port in the system.
All alarming for an ASAI and Avaya adjunct and OFF-BOARD alarming for an ASAI or Avaya port is
disabled if the ASAI or Avaya adjunct asks the switch to suspend maintenance. When this occurs, an error
and a WARNING alarm is logged against the ASAI or Avaya adjunct. The Hardware Error and Alarm Logs
should be checked to see if the adjunct has disabled alarming.
test port location l
ASAI ISDN-BRI port
ABRI-POR
test port location l
ASAI ISDN-BRI port
ATT-PORT
test port location l
Avaya Adjunct ISDN-BRI port
ATT-PORT
WRN
test port location l
Avaya Adjunct ISDN-BRI port
LGATE-PT
test port location l
Ethernet ASAI port
LGATE-PT
WRN
test port location l
Ethernet ASAI port
ATTE-PT
MAJ
test port location l
Ethernet Avaya Adjunct port
ATTE-PT
WRN
test port location l
Ethernet Avaya Adjunct port