BRI-PORT (ISDN-BRI Port)
Issue 1 June 2005
703
 
Electronic Power Feed Inquiry (#622)
This test queries the BRI-LINE circuit pack for the status of the Electronic Power Feed (EPF) 
supplied to a BRI endpoint or an ASAI or Avaya adjunct.  If the EPF is on and no overcurrent 
condition exists, this test passes.  All other states are not normal and indicate a problem with 
the endpoint or adjunct, the wiring to the endpoint or adjunct, or the BRI-LINE circuit pack.  This 
test is not run on the TN2208 circuit pack or the TN2198 and will always return a pass for the 
TN2198.  The TN2208 has no power feeds.
4
FAIL
For the TN2198 only:
Received a status of Level 1 Pending Activation, the NT1 has a loss of 
power indicating a problem with the NT1.
1. For the NT1 follow the manufacturers recommended repair 
procedures.
2. Execute test port location, and review the results of the Level 1 
Status Inquiry test to verify the repair.  If the test is still failing proceed 
to step 3.
3. Escalate the problem to the next tier.
PASS
This test indicates that Level 1 is activated, or that software has taken the 
port out of service.
Table 235: Test #621 Level 1 Status Inquiry  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 4 of 4
Table 236: Test #622 Electronic Power Feed Inquiry 
Error 
Code
Test 
Result
Description / Recommendation
1005
ABRT
This test is not valid for this port type.  Ports on the TN2208 cannot run this 
test because this board does not have an electronic power feed.
2000
ABRT
Response to the test was not received from the circuit pack within the 
allowable time period.
1. If the test aborts repeatedly up to five times, reset the circuit pack via  
busyout board location and reset board location.
2. If the test aborts again, replace the circuit pack.