Avaya 03-300430 User Manual
BRI-PORT (ISDN-BRI Port)
Issue 1 June 2005
705
Table 237: Test #624 Layer 1 Transmission Error Counter Test
Error
Code
Code
Test
Result
Result
Description / Recommendation
2000
ABRT
Response to the test was not received from the circuit pack within the
allowable time period.
allowable time period.
1. If the test aborts repeatedly up to five times, reset the circuit pack via
busyout board location and reset board location.
2. If the test aborts again, replace the circuit pack.
2012
ABRT
Internal system error.
2100
ABRT
Could not allocate necessary system resources to run test.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to fail, escalate the problem.
value
FAIL
The BRI-LINE circuit pack is still detecting errors of this type. The Error
Code field contains the value of this counter.
Code field contains the value of this counter.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to fail, review the results of other tests in the long
test sequence. Pay particular attention to the results of the Level 1
Status Inquiry test. Follow repair procedures for any of the executed
tests if they fail. Otherwise, go to the next step.
Status Inquiry test. Follow repair procedures for any of the executed
tests if they fail. Otherwise, go to the next step.
3. If the tests for the endpoints or adjunct pass and the Layer 1
Transmission Error Counter test continues to fail, check the wiring to
the endpoints or adjunct. If the wiring appears to be fine, escalate the
problem.
the endpoints or adjunct. If the wiring appears to be fine, escalate the
problem.
PASS
The Layer 1 Transmission error counter was read correctly and has a value
of 0.