q. Error 2568: the adjunct ID is invalid, check the vender ID or software running on the Avaya 
adjunct.
System Technician-Demanded Tests:
Descriptions and Error Codes
Investigate errors associated with the circuit pack and port first.  Clearing these error codes first 
may also clear errors generated against the endpoint.  When every circuit pack and port error 
has been cleared, and errors still exist against the endpoint, investigate errors in the order they 
are presented in the table below.  By clearing error codes associated with the Signaling Link 
Status 
test (#626), you may also clear errors generated from other tests in the sequence.
58
Bearer 
Capability Not 
Currently 
Available
Requested bearer capability is implemented, but not administered.  
No B channel is administered.  See recommendation for Error Code 
50 above.
65
Bearer 
Service Not 
Implemented
Requested service not implemented in switch or endpoint.
69
Requested 
Facility Not 
Implemented
Requested service not supported in switch or endpoint.
1. Consult switch and endpoint documentation to determine 
service support.
2. If step 1 does not resolve the problem, escalate to the next tier.
81
Invalid CRV
An invalid CRV was sent by the adjunct.
1. This may indicate a CRV inconsistency between the switch and 
the adjunct.  Refer to the CallVisor protocol reference manual.
2. If step 1 does not resolve the problem, escalate to the next tier.
Table 242: ISDN-BRI CAUSE VALUES; (BRI-SET/ASAI-ADJ Error Log Notes)  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 3 of 3
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
1
Signaling Link Status test (#626)
X
X
ND
BRI XID test (#628)
X
X
ND
BRI Layer 3 Query (#629)
X(a)
X(a)
ND