Avaya 03-300430 User Manual

Page of 2574
Server Alarms
72 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
21
(cont’d)
199
UltraDMA CRC Error 
Count
Count of Cyclic Redundancy Check 
(CRC) errors during UltraDMA mode 
(Samsung, Seagate, IBM (Hitachi), 
Fujitsu - select models, Maxtor, Western 
Digital - select models)
200
Write Error Rate (Multi 
Zone Error Rate
Total number of errors found when writing 
a sector. (Samsung, Seagate, IBM 
(Hitachi), Fujitsu, Maxtor, Western Digital)
220
Disk Shift
Indicates how much the disk has shifted 
(unit of measure unknown). This error is 
critical. An increasing value for this 
error may indicate a failing disk drive. 
(Seagate)
221
G-Sense Error Rate
Rate of errors occurring as a result of 
impact loads such as dropping the drive, 
wrong installation, etc. (Seagate, Hitachi)
222
Loaded Hours
Loading on magnetic heads actuator 
caused by the general operating time.
223
Load/Unload Retry 
Count
Loading on magnetic heads actuator 
caused by numerous recurrences of 
operations like: reading, recording, 
positioning, etc. 
224
Load Friction
Loading of magnetic heads actuator 
caused by friction in mechanical part of 
the store. 
226
Load-in Time
Total time of loading on the magnetic 
heads actuator.
227
Torque Amplification 
Count
Count of efforts of the rotating moment of 
a drive
228
Power-Off Retract 
Count
Count of the number of times the drive 
was powered off. 
230
GMR Head Amplitude
Amplitude of the heads trembling in 
running mode. 
22
WRN
Failed to read smart values/thresholds
This indicates that the smart utility was not able to read the smart values/
thresholds from the drive. The smart utility is unable to function due to drive 
access problems.
Table 17: HDD Alarm in Media Server (continued)
Event
ID
Alarm
Level
Alarm Text, Cause/Description, Recommendation
 4 of 4