Avaya 03-300430 User Manual

Page of 2574
BRI-SET, Various Adjuncts
Issue 1 June 2005
723
 
1187
ABRT
The circuit pack, port or station may have been busied out by a technician.
1. Look in the Error Log for Error Type 18 (busied out) for BRI-BD, 
BRI-PORT, or BRI-SET.
a. If this error type is present for BRI-SET only, then release the station 
via the release station
b. If this error type is present for BRI-PORT and BRI-SET, then release 
the port via release port location and run the test again.
c. If the error is present for BRI-BD, BRI-PORT, and BRI-SET, then 
release the circuit pack via the release port location and run 
the test again.  If the error is present for both BRI-BD and 
BRI-PORT, then release the circuit pack via release board 
location
 and run the test again.  If the error is present for 
BRI-SET only, then release the circuit pack via release port 
location
 and run the test again.
Note:
Note:
When you release the circuit pack, you release every port 
associated with it.  If certain ports still need to be busied out, 
use busyout port location to busy them out.
2. Make sure the terminal is connected.
3. Retry the command at 1-minute intervals up to 5 times.
2012
ABRT
Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
2068
ABRT
The endpoint has rejected the switch sent application message.  This 
indicates that the endpoint does not support the ISDN-BRI Management 
and Maintenance Procedure for Loop Back testing.
1. Use change station extension and set the MIMs Supported 
field to n.
Table 244: Test #627 BRI Remote Loop Back  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 2 of 3