Communication Manager Maintenance-Object Repair Procedures
728 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
1113
ABRT
The signaling link between the switch and the endpoint or adjunct is down.
1. Use test port location long to clear any errors that prevent 
establishment of the signaling link.
2. Examine the results of Test #626 that are executed with the command.  
If this test aborts or fails, follow the repair procedure for the Signaling 
Link Status test.
3. Escalate problem if BRI Layer 3 Query test continues to abort.
1139
ABRT
The PN’s packet bus is out-of-service.
1. Follow the repair procedures for the packet bus.
2. After completing step 1, execute test port location long, and 
review the results of the BRI Port Local LAN Loop Around test (#618) 
to verify the repair.
1141
ABRT
The PKT-CTRL is out-of-service.
1. Consult the repair procedure for PKT-CTRL (Packet Control Circuit 
Pack) Maintenance documentation.
2. If step 1 does not resolve the problem, escalate to the next tier.
Table 246: Test #629 BRI Layer 3 Query  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 2 of 4