Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
740 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Error log entries and test-to-clear values
Table 251: CAB-EXFR Error Log Entries
Notes:
a. Error Type 1 – Manual on. Run test environment location and follow the repair 
steps for Test #1532.
For information on specifying a location, se
b. Error Type 2 – Firmware has activated emergency transfer. This error is not expected. Run 
test environment location and follow the repair steps for Test #1532.
c. Error Type 257 – Manual off. Run test environment location and follow the repair 
steps for Test #1532.
System technician-demanded test:
Descriptions and error codes
Error 
type
Aux 
data
Associated test
Alarm 
level
On/Off 
board
 Test-to-clear value
1 (
)
Emergency transfer 
query test (#1532)
MAJ
On
test environment 
location
2 (
)
Emergency transfer 
query test (#1532)
MAJ
On
test environment 
location
Emergency transfer 
query tesst (#1532) 
WRN
On
test environment 
location
Order of investigation
Short test 
sequence
Long test 
sequence
D/ND
Emergency transfer query test (#1532)
X
X
Nondestructive