Communication Manager Maintenance-Object Repair Procedures
744 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
CAB-MTCE (Media Gateway Maintenance)
G650
 
Avaya Communication Manager 2.0 introduces the G650 media gateway. The G650 media 
gateway does not support the traditional maintenance board (TN775D), therefore 
environmental maintenance is performed by the TN2312BP IPSI circuit pack. The CAB-MTCE 
MO is used to allow the alarming and logging of environmental maintenance errors for the 
TN2312BP IPSI in a G650 media gateway. Since the TN2312BP IPSI supports environmental 
maintenance in the G650 media gateway, trouble with the TN2312BP IPSI may cause 
environmental maintenance to falsely detect problems. The following environmental MOs may 
be affected:
When the TN2312BP is used in the SCC1 and MCC1 media gateways the collocated TN775D 
Maintenance circuit pack performs environmental maintenance. 
When the TN2312BP IPSI is used in a G600 or CMC1 media gateway it monitors environment 
maintenance (power supply and fans) using the AuxSig lead. 
Initialization
Initialization Test (#1548) is executed when an IPSI is inserted and the board and media 
gateway type is determined. When a TN2312AP is inserted in a CMC1, G600, or G650 the 
Power Fan Lead (AuxSig) environmental maintenance is enabled. 
When a TN2312BP IPSI is inserted in either a CMC1 or G600, Communication Manager sends 
the following messages to the embedded software (firmware) on the board:
Enable environmental maintenance (Power Fan lead)
A query to verify that environmental maintenance is enabled 
MO name in 
alarm log
Alarm 
level
Initial SAT command to run
Full name of MO
CAB-MTCE
MIN
test maintenance location sh
Media Gateway 
Maintenance
CAB-MTCE
MAJ
test maintenance location l
Media Gateway 
Maintenance