CAB-MTCE (Media Gateway Maintenance)
Issue 1 June 2005
745
 
When a TN2312BP IPSI is inserted in a G650, Communication Manager sends the following 
messages to embedded software (firmware) on the board:
Enable environmental maintenance
Enable power supply insertion
Enable power supply audits
A query to verify that environmental maintenance is enabled
A query to verify that power supply insertion is enabled
A query to verify that power supply audits are enabled
Error log entries and test-to-clear values
Table 253: CAB-MTCE Error Log Entries
Notes:
a. Error Type 1—When a TN2312AP IPSI is inserted into a CMC1 or G650 Media Gateway a 
minor alarm is raised. Full environmental maintenance is NOT available. Replace the 
TN2312AP IPSI with a TN2312BP IPSI. NOTE: A TN2312AP inserted in a G600 media 
gateway DOES not raise any alarm or error. 
b. Error Type 257—This error indicates the inability to communicate with the TN2312BP IPSI 
board. NOTE: The board must be a TN2312BP IPSI for this test to run. 
c. Error Type 513—This error indicates that the op-code for messages received from the 
TN2312BP was not equal to any known op-code. The unknown op-code is recorded under 
Aux data.
Error 
Type
Aux 
data
Associated test
Alarm 
level
On/
Off 
board
 Test-to-clear value
1 (
Correct board test 
(#1546)
MIN
ON
test maintenance 
location
Sanity test (#1547)
MIN
ON
test maintenance 
location
)
Any
All
NONE
Any
All
NONE
1025 (
Reset test (#1545)
MIN
ON
test maintenance 
location
1281 (
Initialization test 
(#1548)
MIN
ON
reset maintenance 
location