d. Error Type 769—This error indicates that a message with a valid op-code was received but 
some other part of the message was indecipherable. The op-code with the error is recorded 
under Aux data. 
e. Error Type 1025—This error indicates that an unsuccessful attempt was made to reset 
environmental maintenance. 
f. Error Type 1281—This error indicates that environmental initialization failed. Run the 
Reset 
Environmental Maintenance Test
 (#1545), which calls the Initialization Test (#1548).
System technician-demanded tests:
Descriptions and error codes
Investigate tests in the order presented. When you clear error codes associated with the 
Correct Board Test (1546), you might also clear errors generated from other tests in the testing 
sequence.
Reset Environmental Maintenance test (#1545)
This test resets the environmental maintenance on the TN2312BP IPSI board.
 
Order of investigation
Short test 
sequence
Long test 
sequence
D/ND
1
1. D = Destructive, ND = Nondestructive
Correct Board Test (#1546)
X
X
ND
Sanity Test (#1547)
X
X
ND
Reset Environmental Maintenance Test (#1545)
— 
X
D
Table 254: Test #1545 Reset test 
Error 
code
Test 
result
Description and recommendation
1000
ABRT
There is an internal software problem. 
1. Repeat the command at one-minute intervals 1 to 3 times.