Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
750 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
System technician-demanded tests:
Descriptions and error codes
S8700 | 8710
Power/Fan lead query test #(1533)
The Power/Fan Query test sends a request for the state of the power/fan lead (AuxSig) to the 
TN2312BP IPSI board in the G650 with an A carrier address. If the lead is on, the test fails. If 
the lead is off, the test passes.
Order of Investigation
Short test 
sequence
Long test 
sequence
D/ND
Power/Fan lead query test (1533)
X
X
Nondestructive
Table 258: Test 1533 Power/Fan lead query 
Error 
code
Test 
result
Description and recommendation
1000
ABRT
This is an internal system error.
1. Repeat the command at one-minute intervals 1 to 3 times.
2000
ABRT
The response to a query was not received in the time allowed. 
1. Repeat the command at one-minute intervals 1 to 3 times.
1
FAIL
G650
: In a G650 carrier, this indicates a failure in any of the following MOs:
SER-BUS
POW-SUP
CAB-TEMP
PS-RGEN
Use the diagnostic procedures for those MOs to clear the problem.
 1 of 3