Avaya 03-300430 User Manual

Page of 2574
Server Alarms
76 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Back to:              
             
RALM-SVC (Remote Alarm Service)
S8700 | 8710
 only
For the RALM-SVC
 
MO, maintenance software performed special periodic testing every 60 
seconds.
2
MIN
“eth1 NIC Link is Down” — Ethernet link on native NIC 1 is down.
1. Verify Ethernet connectivity, either from the:
- Web interface, by selecting the Execute Pingall diagnostic
- Linux command line, by entering pingall -a
Check both sides of each failed link, and make any necessary repairs.
2. If the ping test fails, check the physical connections of NIC 0’s Ethernet 
cable.
If not, manually clear the alarm, either from the:
- Web interface, by selecting Alarms and Notification, the 
appropriate alarm, and “Clear”
- Linux command line, by entering almclear -n #id
Table 20: NIC Alarms in Media Server (continued)
Event
ID
Alarm
Level
Alarm Text, Cause/Description, Recommendation
 2 of 2
MOs Name Alarm Level
Initial Command to Run
Full Name of MO
RALM-SVC
MAJOR
None
Remote Alarm Service
RALM-SVC
MAJOR
None