Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
762 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
System Technician-Demanded Tests:
Descriptions and Error Codes
S8700 | 8710
 / 
S8500
Investigate tests in the order presented. By clearing error codes associated with one test, you 
may clear errors generated from later tests in the sequence.
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
1
1. D = Destructive; ND = Nondestructive
 Battery & Battery Charger Query test (#5)
X
X
ND
AC Power Query test (#78) See 
X
X
ND
OLS Query test (carrier E) (#127)  
See 
X
X
ND
OLS Query test (carrier D) (#127) 
See 
X
X
ND
OLS Query test (carrier A) (#127) 
See 
X
X
ND
OLS Query test (carrier B) (#127) 
See 
X
X
ND
OLS Query test (carrier C) (#127) 
See 
X
X
ND
Emergency Transfer Query test (#124) 
See 
X
X
ND
Cabinet Temperature Query test (#122) 
See 
X
X
ND
External Alarm Lead Query test (#120) 
See 
X
X
ND
Analog Ring Generator Initial test (#117) 
See 
X
X
ND
Analog Ring Generator Query test (#118) 
See 
X
X
ND