Server Alarms
78 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
SME Alarm in S8700 Media Server
on page 78 describes the SME alarm (for RALM-SVC 
(Remote Alarm Service) and its troubleshooting procedures.
Back to:              
             
Table 22: SME Alarm in Media Server 
Event
ID
Alarm
Level
Alarm Text, Cause/Description, Recommendation
1
MAJ
“Far-end alarm service is down” — No remote alarm service is available 
since the other server is unable to report alarms — due to a failure of either 
the GMM or administered reporting mechanisms (SNMP and/or modem).
1. Look for any GMM failures on the other server, either using the:
- Web interface, by selecting Diagnostics > View System Logs and 
Watchdog Logs
- Linux command line, by entering logv -w or, directly, by examining 
/var/log/ecs/wdlog.
2. If a GMM failure was found:
a. See if the GMM application is up, either from the:
- Web interface, by selecting View Process Status
- Linux command line, by entering statapp
b. If so, continue with Step 
If not, try to restart this application by entering start -s GMM on the 
Linux command line.
c. If the GMM application successfully restarts, continue with Step 
If notescalate the problem to the next higher tier.
3. If a GMM failure was not found, see if alarm reporting failed by looking in 
the trace log for a string that includes “snd2Inads”, either from the:
- Web interface, by:
a. Selecting the View System Logs diagnostic and Logmanager 
Debug trace
b. Specifying the “Event Range” for the appropriate time frame
c. Matching the “snd2Inads” pattern
- Linux command line, by entering logv -t ts
4. Test the administered reporting mechanisms, by entering testinads 
on the Linux command line.
5. Once the alarm is resolved, manually clear the alarm, either from the:
- Web interface, by selecting Alarms and Notification, the appropriate 
alarm, and Clear
- Linux command line, by entering almclear -n #id