Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
800 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Control Channel Loop-Around Test (#52)
This nondestructive test fails if the circuit pack does not return to a sane state after being reset.  
This test queries the circuit pack for its code and vintage, and verifies its records.
Table 270: Test #52 Control Channel Loop-Around Test 
Error 
Code
Test 
Result
Description / Recommendation
None, 
2100
ABRT
Could not allocate the necessary system resources to run test.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the problem persists, escalate the problem.
FAIL
The circuit pack failed to return the code or vintage.
1. Retry command at 1-minute intervals up to 5 times.
2. Reset the board with reset board location.
3. If reset aborts with error code 1115, busyout (busyout board 
location), reset with reset board location, and release board 
(release board location).
4. If test continues to fail, replace the circuit pack.
5. Escalate the problem if failures continue.
PASS
Test successful.